16.1 General specifications
Conductivity/resistivity ranges
0.01 cm
–1
constant sensor 0.002 to 200 µS/cm (5000Ω x cm to 500 MΩ x cm)
0.1 cm
–1
constant sensor 0.02 to 2000 µS/cm (500Ω x cm to 50 MΩ x cm)
10 cm
–1
constant sensor 10 to 40,000 µS/cm (25Ω x cm to 100 KΩ x cm)
4-electrode sensor 0.01 to 650 mS/cm (1.54Ω x cm to 0.1MΩ x cm)
Chemical concentration curves HCI, NaOH, H2SO4: 0–20%, 0–15%, 0–20%
TDS range (CaCO3 and NaCl) Covers equivalent conductivity ranges
Temperature input PT 1000
Temperature measuring range –40 to + 200.0 °C (–40 to 392 °F)
Sensor maximum distance 61 m (200 ft); 15 m (50 ft with 4-E sensors)
Cond/Res accuracy ± 0.5% of reading or 0.25Ω, whichever is greater,
Up to 10 MΩ-cm
Repeatability ± 0.1% of reading for resistance
Resolution 0.001 (four significant digits)
Temperature resolution 0.1 °C ( 0.1 °F)
Temperature relative accuracy ± 0.25°C (± 0.45 °F)
Temperature repeatability ± 0.13°C (± 0.23 °F)
Ratings/Approvals UL Listed, CE Compliant
16.2 Electrical specifications for 1/2DIN and 1/4DIN versions
Power requirements 100 to 240 V AC or 20 to 30 V DC, 5 W
Frequency 50 to 60 Hz
Analog output signals
Single Channel = Two, Dual Channel = Four
0/4 to 22 mA outputs for Conductivity/
Resistivity and temperature, galvanically
isolated from input and from earth/ground
Measurement Error through analog outputs < 0.5% of full scale
Analog output configuration Linear, Bi-Linear, Logarithmic, Autoranging
Load max. 500 Ω
Connection terminals Detachable screw terminals
Digital communication USB port, Type B connector
PID process controller Pulse length, pulse frequency or analog control
Connection terminals Detachable screw terminals
Digital Input Single Channel =1, Dual Channel = 2
Mains power fuse 1.0 A slow blow type FC
Relays
2-SPDT mechanical 250VAC, 30 VDC,
3 Amps resistive
2-Reed 250VAC or DC, 0.5 A, 10 W
2-SPST mechanical rated at 250VAC,
3Amps (Dual Channel only)
Alarm Relay delay 0 – 999 s
Keypad 5 tactile feedback keys
Display four-line